SolarIV Pro-X5 · Reveal the true performance of every module
Shows the real performance of PV modules from different manufacturers, batches and technology routes, for distributors, O&M teams, quality inspection and third-party testing.
SolarIV Pro-X5 main unit · 8.8-inch IPS capacitive touchscreen The SolarIV Pro-X5 is a field I-V curve tracer for PV modules. It measures two modules at once, either synchronized or in automatic cross-test, so modules from different manufacturers, batches and technology routes can be compared under the same conditions.
It captures I-V data at 1 W/m² irradiance resolution, returns a result in as fast as about 3 seconds, and provides four power-tracing control modes with evaluation across five dimensions. Each test reports Voc, Isc, Vmp, Imp, Pmax and fill factor FF, and plots I-V and P-V curves.
Tests can run automatically against a time sequence, sampling interval and irradiance limits. The host works on its own, including in a multi-unit setup, and keeps the task running if the phone or tablet disconnects. Module identity, site images and the raw record of every round stay linked, and bilingual Chinese/English reports can be generated at module, analysis and project level.
Measure two modules at the same time and compare them under identical conditions. I-V and P-V curves are drawn as the test runs, so the readings can be read together.
The instrument switches channels internally, so there is no manual rewiring and the comparison stays consistent. Module ID, channel and the raw record of every round are kept together for traceability.
Set a time sequence, sampling interval and irradiance limits, then choose synchronized or cross testing. The host runs the plan on its own, can join other units, and continues if the controller disconnects.
Module ID, images and test records stay linked. Filtering, statistics and trend comparison are built in, and Chinese/English reports can be exported at module, analysis and project level.
Compare modules from different manufacturers, batches and technology routes under the same conditions, with I-V and P-V curves side by side.
Find underperforming modules on site. Cross testing needs no rewiring, and every round of raw data is kept for review.
A default 100-point cross test presents Voc, Isc, Vmp, Imp, Pmax and fill factor in about 3 seconds.
eSTC is estimated from a reference module, irradiance and ambient temperature, with traceable records for acceptance checks. It is not a laboratory STC result.
I-V and P-V curves are shown side by side under identical conditions: measured Pmax corroborates the eSTC estimation, while fill factor and related indicators complete a five-dimension performance assessment.
Front-panel deployment and rear internal structure — see the unit in the field and the components inside.
Front view of the unit in a PV plant, industrial tech aesthetic.
Rear structure and circuit details of the measurement unit.
| Max power Pmax | ≤ 800 W |
| Open-circuit voltage Voc | ≤ 75 V |
| Short-circuit current Isc | ≤ 20 A |
| Voltage range | 0 – 75 V |
| Current range | 0 – 20 A |
| Voltage | ±(0.5% of reading + 0.05 V) |
| Current | ±(0.5% of reading + 0.05 A) |
| Power | ±(0.5% of reading + 0.5 W) |
| Points per channel / round | 100 / 200 / 300 / 400 / 500 |
| Synchronized mode | 1 s – 5 s |
| Cross mode | about 2 s – 10 s (two rounds) |
| Default fast test | 100-point cross test, result in about 3 s (10 ms/point) |
| Parameters | Voc / Isc / Vmp / Imp / Pmax / FF |
| Charts | I-V and P-V curves |
| Mobile control | Android app or mini-program over Wi-Fi or Type-C, on a tablet or phone |
| On-device control | The built-in screen runs the test alone, including after the controller disconnects |
| Seven modules | Projects, test records, analysis, reports, settings, module library, device management |
| Data formats | Raw I-V, CSV, Excel, PDF |
| Report levels | Module measurement, data analysis and project, in Chinese and English |
| Analysis | Built-in BI charts, Pmax energy integration, and eSTC estimation |
| Screen | 8.8-inch IPS capacitive touchscreen (1920 × 480) |
| Storage | 32 GB SD card included, expandable |
| Adapter | 12 V / 1 A |
| Power bank | Supported, 5 V at 2 A or higher |
| External UPS | 12 V output, 10,000 mAh LFP, about 10 h; shares the dedicated 12 V port with the adapter |
| Links | RS485 / GPS / Wi-Fi |
| Connectors | XT60 (XT60-to-MC4 cable included), Type-C, 4-pin RS485 |
| Dimensions | 270 × 260 × 85 mm |
| Weight | about 4.5 kg including the external UPS |
| Operating temperature | −20 to +45 °C |
| Intended market | China |
| Host | ×1 |
| PV leads | ×2 |
| Power adapter | ×1 |
| External UPS | ×1 |
| Bracket | ×1 |
| Manual | ×1 |
| Optional irradiance sensor | Hukx SR05-D1A3; RS485 / Modbus RTU; 0 – 2000 W/m²; 1 W/m² resolution; ±5% accuracy |
| Sample timing | 10 ms per point; 100 points take 1 s. |
| Runtime | 10 h on the 10,000 mAh UPS is a typical-condition figure and depends on actual use. |
| eSTC | eSTC is estimated from a reference module, the irradiance sensor and ambient temperature. It is not a laboratory STC result. |
| Sensor figures | Irradiance resolution and accuracy follow the sensor manufacturer’s datasheet and are pending archive check. |